Back to top
FIAflex cTnl/CK-MB/Myo FIA 25Test PEERCHECK
FIAflex cTnl/CK-MB/Myo FIA 25Test PEERCHECK

FIAflex cTnl/CK-MB/Myo FIA 25Test PEERCHECK

Price 44180.0 INR/ Box

MOQ : 1 Box

FIAflex cTnl/CK-MB/Myo FIA 25Test PEERCHECK Specification

  • Material
  • Plastic and test strip materials
  • Condition
  • New
  • Technology
  • Fluorescence Immunoassay (FIA)
  • Portable
  • Yes
  • Disposable
  • Yes
  • Wall Mounted
  • No
  • Display Type
  • Not Applicable (used with compatible reader)
  • Sensor
  • Embedded in test strip
  • Software Detail
  • Used with compatible FIA analyzer software
  • Measurement
  • Qualitative/Quantitative detection of cTnI, CK-MB, Myoglobin
  • Data Transmission Mode
  • With external analyzer and connectivity
  • Synchronize With
  • Compatible reader/analyzer unit
  • Real-Time Operation
  • Yes
  • Noise Level
  • Silent operation
  • Operating Type
  • Manual with analyzer
  • Size
  • Standard test strip size, box of 25 tests
  • Weight
  • Approx. 250g per box
  • Color
  • White (test strip), Teal/white (packaging)
  • Attributes
  • High sensitivity, easy sample loading
  • Usage
  • For professional use in rapid cardiac marker detection
  • Intended Use
  • In vitro diagnostic for cardiac biomarker detection
  • Test Format
  • Lateral flow immunoassay cassette
  • Packaging
  • Box of 25 individually packed tests
  • Sample Type
  • Whole blood, plasma, or serum
  • Safety
  • Non-toxic, single use only
  • Storage Temperature
  • 2C-30C
  • Test Types
  • cTnI (Cardiac Troponin I), CK-MB (Creatine Kinase MB), Myoglobin
  • Time to Result
  • Approx. 15 minutes
  • Shelf Life
  • 18-24 months (refer to pack label)
  • Reading Method
  • Requires FIAflex compatible fluorescence analyzer
 
 

FIAflex cTnl/CK-MB/Myo FIA 25Test PEERCHECK About

The FIAflex cTnI/CK-MB/Myo test is a rapid, quantitative fluorescence immunoassay used to diagnose and assess myocardial injury, such as a heart attack (Acute Myocardial Infarction, or AMI)
. It is performed using a dedicated immunoassay analyzer and a test kit.
The reference to "FIFA 25" in your query appears to be a typo for "FIA 25," which designates the test kit size (25 tests).
Key features
  • Principle: The test uses Time-Resolved Fluorescence Immunoassay (TR-FIA) technology, which offers higher sensitivity and accuracy than conventional methods. It employs Europium ions (
    Eu3+cap E u raised to the 3 plus power
    3+
    ) as fluorescent particles, which are read by the analyzer after background fluorescence has decayed.
  • Biomarkers measured: This single test detects and quantifies three important cardiac biomarkers in a patient's blood sample:
    • Cardiac Troponin I (cTnI): Highly specific for heart muscle damage. Levels rise 4 to 6 hours after a heart attack, peak at 8 to 28 hours, and remain elevated for 3 to 10 days.
    • Creatine Kinase-MB (CK-MB): An enzyme found in the heart. Its level rises 4 to 6 hours after a heart attack, peaks at 10 to 24 hours, and returns to normal within 3 to 4 days.
    • Myoglobin (Myo): A protein found in heart and skeletal muscle. Due to its small size, it is released into the bloodstream quickly after injury, with levels rising within 2 to 4 hours.
  • Intended use: The test is used as an aid in the clinical diagnosis, prognosis, and management of myocardial injury related to:
    • Acute Myocardial Infarction (AMI)
    • Unstable Angina
    • Acute Myocarditis
    • Acute Coronary Syndrome (ACS)
  • Sample type: The test can be performed on whole blood, serum, or plasma samples.


Accurate Cardiac Marker Detection

FIAflex cTnl/CK-MB/Myo provides reliable results for Cardiac Troponin I, CK-MB, and Myoglobin, essential markers in diagnosing acute cardiac events. Its fluorescence immunoassay technique ensures high sensitivity, empowering clinicians to make timely and informed treatment decisions.


Quick and Convenient Testing

Offering results in approximately 15 minutes, this kit supports rapid clinical workflows. Its user-friendly design allows easy sample loading with no complex preparation steps. Tests are individually packed for convenience, helping maintain high hygiene and usability standards.


Flexible Sample Types

This kit accepts whole blood, plasma, or serum samples, granting versatility in different clinical scenarios. Its compatibility with various common sample types enhances its utility across a range of healthcare environments.

FAQ's of FIAflex cTnl/CK-MB/Myo FIA 25Test PEERCHECK:


Q: How do I use the FIAflex cTnl/CK-MB/Myo FIA test kit?

A: To use the test, load a sample of whole blood, plasma, or serum onto the lateral flow immunoassay cassette, then insert it into the compatible FIAflex fluorescence analyzer. Follow the included instructions for sample preparation and analyzer operation to ensure optimal results.

Q: What does the test detect and how is it beneficial?

A: This kit qualitatively and quantitatively detects cTnI, CK-MB, and Myoglobin-three important cardiac biomarkers. Early detection aids in the rapid diagnosis and management of acute myocardial infarction and other cardiac events, benefitting patient care.

Q: When should I use this test kit in a clinical setting?

A: The kit is intended for use when speedy detection of cardiac biomarkers is required, such as for patients presenting with chest pain or symptoms of cardiac distress. It provides critical results in about 15 minutes.

Q: Where should the test and reagents be stored?

A: Store the test kit and components at a temperature between 2C and 30C. Always refer to the packaging label for specific storage information to maintain product efficacy throughout its 18-24 month shelf life.

Q: What equipment is required to read the results?

A: The test strips must be used with a FIAflex-compatible fluorescence analyzer and its corresponding software. These analyzers enable both qualitative and quantitative reading of the cardiac biomarkers.

Q: Who can use the FIAflex cTnl/CK-MB/Myo FIA test kit?

A: This kit is designed strictly for professional use by healthcare providers in clinical or laboratory settings, ensuring accurate sample handling and interpretation.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Rapid Testing Kit Category

FIAflex CK-MB FIA Test 25T

FIAflex CK-MB FIA Test 25T

Price 15500.0 INR / Box

Minimum Order Quantity : 10 Boxes

Size : Standard Cassette Size

Color : White Cassette, Teal Box

12 Lead ECG Device

12 Lead ECG Device

Minimum Order Quantity : 100 Pieces

Size : Various Available

Color : Various Available

Storage Instructions : Clean Place

Use : Hospitals

Typhoid Antibody (IgG & IgM) Rapid Test / 30 Tests Kit  - PEERCHECK

Typhoid Antibody (IgG & IgM) Rapid Test / 30 Tests Kit - PEERCHECK

Price 3550.0 INR / Box

Minimum Order Quantity : 10

Size : Various Available

Color : Various Available

Storage Instructions : Clean Place

Use : Hospitals

HCV Antibody Test Device

HCV Antibody Test Device

Minimum Order Quantity : 100 Pieces

Size : Various Available

Color : Various Available

Storage Instructions : Clean Place

Use : Hospitals